Серия KFA…, KFD0…

Барьеры, усилители, разделительные усилители, преобразователи, контроллеры, электронные реле контроля состояний и отклонений, блоки/модули питания серий KFA…, KFD0…

Описание

Продукт Краткое описание Datasheet
Разделительный усилитель
KFA4-SR2-Ex1.W
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay output with 1 changeover contact, EMC acc. to NAMUR NE 21, LB/SC monitoring, Usable up to SIL 2 acc. to IEC 61508 , Input: NAMUR sensor, Rated voltage: 90 … 110 V AC , 45 … 65 Hz, Output: relay, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель
KFA4-SR2-Ex1.W.LB
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, Output I: signal output (changeover contact), Output II: optionally signal output/fault signal, EMC acc. to NAMUR NE 21, LB/SC monitoring, Usable up to SIL 2 acc. to IEC 61508 , Input: NAMUR sensor, Rated voltage: 90 … 110 V AC , 45 … 65 Hz, Output: relay, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель
KFA4-SR2-Ex2.W
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay output with 1 changeover contact per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, Usable up to SIL 2 acc. to IEC 61508 , Input: NAMUR sensor, Rated voltage: 90 … 110 V AC , 45 … 65 Hz, Output: relay, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель,
Реле времени
KFA5-DU-Ex1.D
1-channel, Control circuit EEx ia IIC, Switching amplifier with timing, Maximum input frequency 80 Hz, 1 relay output, 1 potential-free electronic output, Pulse divider up to 1 kHz, Time function: one shot output, one shot output retrigger, pulse extension, pulse limitation , on-delay, off-delay, auxiliary switch, Time range of the output function from 10 ms … 60 min, Reset function, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Input: NAMUR sensor, Rated voltage: 115 V AC +/- 10 %
Модуль контроля частоты импульсов,
Контроллер частоты вращения
KFA5-DWB-1.D 
1-channel, Input frequency 1 mHz … 12 kHz, 2 relay outputs, Each output individually parameterisable as trip value, Start-up override, Restart inhibit, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Bounce filter, Parameterisation via control panel, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Function(P2P): Limit value, Output: 2 x 1 Changeover contact, Display, Explosion protection: No Ex-protection
Модуль контроля частоты импульсов,
Контроллер частоты вращения
KFA5-DWB-Ex1.D
1-channel, Control circuit EEx ia IIC, Input frequency 0.001 Hz … 5 kHz, 2 relay outputs, Each output individually parameterisable as trip value, Start-up override, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Restart inhibit, Bounce filter, Parameterisation via control panel, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Function(P2P): Limit value, Output: 2 x 1 Changeover contact, Display, Explosion protection: Ex-Input
Электродное реле (реле коннтроля на прикосновение)
KFA5-ER-1.5
1-channel, Relay for conductive limit value detection, Adjustable sensitivity, Measuring circuit in acc. with VDE 0100 part 410 ‘Funktionskleinspannung’, Minimum/maximum control
Электродное реле (реле коннтроля на прикосновение)
KFA5-ER-1.6
1-channel, Relay for conductive limit value detection, Adjustable sensitivity, Measuring circuit in acc. with VDE 0100 part 410 ‘Funktionskleinspannung’, Minimum/maximum control
Электродное реле (реле коннтроля на прикосновение)
KFA5-ER-1.W.LB
1-channel, Relay for conductive limit value detection, Minimum/maximum control, On/off control system, Open/closed circuit current principle switchable
Электродное реле (реле коннтроля на прикосновение)
KFA5-ER-2.W.LB
2-channel, Relay for conductive limit value detection, Minimum/maximum control, On/off control system, Open/closed circuit current principle switchable
Электродное реле (реле коннтроля на прикосновение)
KFA5-ER-Ex1.W.LB
1-channel, Relay for conductive limit value detection, Minimum/maximum control, On/off control system, Open/closed circuit current principle switchable
Разделительный усилитель
KFA5-SOT2-Ex2
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 passive transistor output, depolarized per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 103.5 … 126.5 V AC, Output: Optocoupler, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель
KFA5-SR2-Ex1.W
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay output with 1 changeover contact, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 103.5 … 126 V AC , 45 … 65 Hz, Output: Relay, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель
KFA5-SR2-Ex1.W.LB
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, Output I: signal output (changeover contact), Output II: optionally signal output/fault signal, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 103.5 … 126 V AC , 45 … 65 Hz, Output: Relay, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель
KFA5-SR2-Ex2.W
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay output with 1 changeover contact per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 103.5 … 126 V AC , 45 … 65 Hz, Output: Relay, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель
KFA5-SR2-Ex2.W.IR
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 signal output with 2 changeover contacts, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 103.5 … 126 V AC , 45 … 65 Hz, Output: Relay, Interval relay, Explosion protection: Ex-Input
Разделительный усилитель,
Реле времени
KFA6-DU-Ex1.D
1-channel, Control circuit EEx ia IIC, Switching amplifier with timing, Maximum input frequency 80 Hz, 1 relay output, 1 potential-free electronic output, Pulse divider up to 1 kHz, Time function: one shot output, one shot output retrigger, pulse extension, pulse limitation , on-delay, off-delay, auxiliary switch, Time range of the output function from 10 ms … 60 min, Reset function, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Input: NAMUR sensor, Rated voltage: 230 V AC +/- 10 %
Модуль контроля частоты импульсов,
Контроллер частоты вращения
KFA6-DWB-1.D
1-channel, Input frequency 1 mHz … 12 kHz, 2 relay outputs, Each output individually parameterisable as trip value, Start-up override, Restart inhibit, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Bounce filter, Parameterisation via control panel, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Function(P2P): Limit value, Output: 2 x 1 Changeover contact, Display, Explosion protection: No Ex-protection
Модуль контроля частоты импульсов,
Контроллер частоты вращения
KFA6-DWB-Ex1.D
1-channel, Control circuit EEx ia IIC, Input frequency 0.001 Hz … 5 kHz, 2 relay outputs, Each output individually parameterisable as trip value, Start-up override, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Restart inhibit, Bounce filter, Parameterisation via control panel, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Function(P2P): Limit value, Output: 2 x 1 Changeover contact, Display, Explosion protection: Ex-Input
Электродное реле (реле коннтроля на прикосновение)
KFA6-ER-1.5
1-channel, Relay for conductive limit value detection, Adjustable sensitivity, Measuring circuit in acc. with VDE 0100 part 410 ‘Funktionskleinspannung’, Minimum/maximum control
Электродное реле (реле коннтроля на прикосновение)
KFA6-ER-1.6
1-channel, Relay for conductive limit value detection, Adjustable sensitivity, Measuring circuit in acc. with VDE 0100 part 410 ‘Funktionskleinspannung’, Minimum/maximum control
Электродное реле (реле коннтроля на прикосновение)
KFA6-ER-1.W.LB
1-channel, Relay for conductive limit value detection, Minimum/maximum control, On/off control system, Open/closed circuit current principle switchable
Электродное реле (реле коннтроля на прикосновение)
KFA6-ER-2.W.LB
2-channel, Relay for conductive limit value detection, Minimum/maximum control, On/off control system, Open/closed circuit current principle switchable
Электродное реле (реле коннтроля на прикосновение)
KFA6-ER-Ex1.W.LB
1-channel, Relay for conductive limit value detection, Minimum/maximum control, On/off control system, Open/closed circuit current principle switchable
Разделительный усилитель
KFA6-SOT2-Ex2
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 passive transistor output, depolarized per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 207 … 253 V AC, Output: Optocoupler, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель
KFA6-SR-2.3L
2-channel, 90 V AC bis 253 V AC wide range power pack, Input for contacts, PNP/NPN sensors or push-pull output stages, 2-channel switching amplifier with 1 changeover contact each, Selectable min/max control (bistable control), Signal doubling: one input is switching both relay outputs (not for min/max control), Reversible mode of operation, Both channels separate adjustable, Input: Contact, Rated voltage: 90 … 253 V AC , 45 … 65 Hz, Output: Relay, Interval relay
Разделительный усилитель
KFA6-SR-2.3L.FA
2-channel, 90 V AC bis 253 V AC wide range power pack, Input for contacts, PNP/NPN sensors or push-pull output stages, 2-channel switching amplifier with 1 changeover contact each, Selectable min/max control (bistable control)
Разделительный усилитель
KFA6-SR2-Ex1.W
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay output with 1 changeover contact, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 207 … 253 V AC, 45 … 65 Hz, Output: Relay, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель
KFA6-SR2-Ex1.W.LB
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, Output I: signal output (changeover contact), Output II: optionally signal output/fault signal, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 207 … 253 V AC, 45 … 65 Hz, Output: Relay, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель
KFA6-SR2-Ex2.W
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay output with 1 changeover contact per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 207 … 253 V AC, 45 … 65 Hz, Output: Relay, SIL/IEC 61508, Explosion protection: Ex-Input
Разделительный усилитель
KFA6-SR2-Ex2.W.IR
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, Bistable, 1 signal output with 2 changeover contacts, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 207 … 253 V AC, 45 … 65 Hz, Output: Relay, Interval relay, Explosion protection: Ex-Input
Напряжение питания
KFA6-STR-1.24.4
Switched power supply, cUL approval, 230 V AC/115 V AC mains nominal voltage, 24 V DC output voltage, Output current max. 4 A, Output voltage on: LED green, Error message: LED flashing red, Removable terminals and Power Rail, Rated voltage: 92 … 265 V AC , 47 … 63 Hz, Explosion protection: No Ex-protection, Current: 0 … 4 A , Power Rail limiting by means of fuse 4 AT , electron. limitation typ. 4.6 A
Напряжение питания
KFA6-STR-1.24.500
Switched power supply, 230 V AC/115 V AC mains nominal voltage, 24 V DC output voltage, Max. output current 500 mA, No ground connection required, Removable terminals and Power Rail, Rated voltage: 90 … 253 V AC , 48 … 63 Hz, Explosion protection: No Ex-protection, Current: 500 mA at 60 °C , permanent short-circuit protection (electronically)
Преобразователь ток/напряжение
KFD0-CC-1
1-channel, Loop powered 12 V DC … 35 V DC, Galvanic isolated measuring circuits, Current range (0/4 mA … 20 mA) or voltage range (0/1 V … 5 V, 0/2 V … 10 V) adjustable via DIP switch, fine tuning (approx. 1%) of the span and zero point possible via DIP switch, Fine adjustment (approx. 1 %) of the span and of the zero point is possible using a potentiometer, Output: 4 mA … 20 mA, EMC acc. to NAMUR NE 21, Input: Current/voltage, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA
Преобразователь ток/напряжение
KFD0-CC-Ex1
1-channel, Input EEx ia IIC, Loop powered 12 V DC … 35 V DC, Galvanic isolated measuring circuits, Current range (0/4 mA … 20 mA) or voltage range (0/1 V … 5 V, 0/2 V … 10 V) adjustable via DIP switch, fine tuning (approx. 1%) of the span and zero point possible via DIP switch, Fine adjustment (approx. 1 %) of the span and of the zero point is possible using a potentiometer, Output: 4 mA … 20 mA, EMC acc. to NAMUR NE 21, Input: Current/voltage, Rated voltage: 12 … 35 V DC loop powered
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-1.50
Galvanic isolated measuring circuits, Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: No Ex-protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: To the field
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-2.50
Galvanic isolated measuring circuits, Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: No Ex-protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-Ex1.50P
Output EEx ia IIC, Device installation permissible in zone 2, Polarity reversal protected, Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: To the field
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-Ex1.51P
Output EEx ia IIC, Device installation permissible in zone 2, Polarity reversal protected, Accuracy 1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex protection, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: To the field
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-Ex1.52
Transmission range: 4 mA … 20 mA, Accuracy 0.1 %, Input EEx ia IIC, Device installation permissible in zone 2, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: loop powered, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: To the control system
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-Ex1.53
Transmission range: 0 mA … 40 mA, Low voltage drop, Accuracy 1 %, Output EEx ia IIC, Device installation permissible in zone 2, EMC acc. to NAMUR NE 21, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex protection, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-Ex1.54
For fire alarm in ‘SMART technology’, Transmission range: 1 mA … 20 mA, Input EEx ia IIC, Device installation permissible in zone 2, Loop powered, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: loop powered, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: To the field
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-Ex2.50P
For fire alarm in ‘SMART technology’, Transmission range: 1 mA … 20 mA, Input EEx ia IIC, Device installation permissible in zone 2, Loop powered, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: loop powered, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: To the field
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-Ex2.51P
Output EEx ia IIC, Device installation permissible in zone 2, Polarity reversal protected, Accuracy 1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex protection, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: To the field
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-Ex2.52
Transmission range: 4 mA … 20 mA, Accuracy 0.1 %, Input EEx ia IIC, Device installation permissible in zone 2, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: loop powered, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: To the control system
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-Ex2.53
Transmission range: 0 mA … 40 mA, Low voltage drop, Accuracy 1 %, Output EEx ia IIC, Device installation permissible in zone 2, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex protection, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: To the field
Преобразователь постоянного тока без вспомогательной энергии
KFD0-CS-Ex2.54
For fire alarm in ‘SMART technology’, Transmission range: 1 mA … 20 mA, Input EEx ia IIC, Device installation permissible in zone 2, Loop powered, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: loop powered, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: To the field
HART-Multiplexer-Slave
KFD0-HMS-16
No external power supply, Up to 16 analogue transmitters can be connected, SIL1 up to SIL3 acc. to IEC 61508
Принадлежности
KFD0-LC-1
Преобразователь сопротивления в ток
KFD0-RC-Ex1
1-channel, Input EEx ia IIC, Loop powered 12 V DC … 35 V DC, Galvanic isolated measuring circuits, Resistance input, 3-wire connection for lead compensation, Lead breakage monitoring, EMC acc. to NAMUR NE 21, Input: Resistance, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA, Output, current sink, Explosion protection: Ex-Input
Релейный модуль
KFD0-RO-Ex2
2-channel, Control circuit EEx ia IIC, Outputs for switching intrinsically safe circuits up to 60 V, Device installation permissible in zone 2, Inputs non-polarised, LED status indicator of relays, Input: 24 V DC, Output: relay, SIL/IEC 61508, Explosion protection: Ex-Input
Релейный модуль
KFD0-RSH-1
1-channel, 1 safety-oriented active electronic output SIL3 acc. to IEC/EN 61508 and acc. to DIN VDE 0660, part 209, Product classification in accordance with ISO 13849-1 (EN 954-1 category 3), Output in fail-safe technology, Input non-polarised, Relay LED status indication, Input: 24 V DC, Output: Relay, SIL/IEC 61508, Explosion protection: No Ex-protection
SMART-разделительный преобразователь
KFD0-SCS-Ex1.55
1-channel, Field circuit EEx ib IIC, Loop powered, Transmission range: 4 mA … 20 mA, Lead monitoring, Conductive for HART communication (galvanically isolated), Universal application for transmitters, position controllers and I/P converters, Only 5 V voltage drop, Test sockets for HART, EMC acc. to NAMUR NE 21, Rated voltage: loop powered, SIL/IEC 61508, HART transfer, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: To the field
SMART-разделительный преобразователь
KFD0-SCS-Ex1.55
1-channel, Field circuit EEx ib IIC, Loop powered, Lead monitoring, Suitable for HART communication (galvanically isolated), Universal application for transmitters, position controllers and I/P converters, Only 5 V voltage drop, Test sockets for HART, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, Rated voltage: loop powered, SIL/IEC 61508, HART transfer, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field

Дополнительная