Продукт |
Краткое описание |
Datasheet |
Преобразователь для термоэлемента Pt100
KFD0-TR-1 |
1-channel, Loop powered 12 V DC … 35 V DC, Galvanic isolated measuring circuits, Input for Pt100 2- or 3-wire, Sensor burnout monitoring, Output, thermally linear, Span can be adjusted from 25 °C … 800 °C, with linearisation from 20 °C … 375 °C, EMC acc. to NAMUR NE 21, Input: Resistance, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA, Output, current sink, Explosion protection: No Ex-protection |
|
Преобразователь для термоэлемента Pt100
KFD0-TR-Ex1 |
1-channel, Input EEx ia IIC, Loop powered 12 V DC … 35 V DC, Galvanic isolated measuring circuits, Input for Pt100 2- or 3-wire, Sensor burnout monitoring, Output, thermally linear, Span can be adjusted from 25 °C … 800 °C, with linearisation from 20 °C … 375 °C, EMC acc. to NAMUR NE 21, Input: Resistance, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA, Output, current sink, Explosion protection: Ex-Input |
|
Преобразователь для термоэлементов
KFD0-TT-1 |
1-channel, Loop powered 12 V DC … 35 V DC, Galvanic isolated measuring circuits, Thermocouples E, J, K, N, R, S, T, Lead monitoring, Output voltage is linearly proportionate to input voltage, Internal cold junction, Span and zero point adjustable, EMC acc. to NAMUR NE 21, Input: thermocouple, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA, Output, current sink, Explosion protection: No Ex-protection |
|
Преобразователь для термоэлементов
KFD0-TT-Ex1 |
1-channel, Input EEx ia IIC, Loop powered 12 V DC … 35 V DC, Galvanic isolated measuring circuits, Thermocouples E, J, K, N, R, S, T, Lead monitoring, Output voltage is linearly proportionate to input voltage, Internal cold junction, Span and zero point adjustable, EMC acc. to NAMUR NE 21, Input: thermocouple, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA, Output, current sink, Explosion protection: Ex-Input |
|
Преобразователь ток/напряжение
KFD0-VC-1.10 |
1-channel, Loop powered 12 V DC … 35 V DC, Galvanic isolated measuring circuits, Output: 4 mA … 20 mA, Fine tuning for span and zero point, EMC acc. to NAMUR NE 21, Input: Current/voltage, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA, Output, current sink, Explosion protection: No Ex-protection |
|
Преобразователь ток/напряжение
KFD0-VC-1.50m |
1-channel, Loop powered 12 V DC … 35 V DC, Galvanic isolated measuring circuits, Output: 4 mA … 20 mA, Lead monitoring, Fine tuning for span and zero point, EMC acc. to NAMUR NE 21, Input: Current/voltage, Rated voltage: 12 … 35 V DC loop powered, Output: 4-20 mA, Output, current sink, Explosion protection: No Ex-protection |
|
Сегментный согласователь Modbus RTU-Segment – Modbus RS 485
KFD2-BR-1.MOD |
Segment coupler for MODBUS RTU, Segment coupler for a non-instrinsically safe MODBUS RTU segment, MODBUS RTU IEC 61158-2, 31.25 kBit/s, Master independent, Up to 32 devices can be connected to the MODBUS RTU segment , 24 V DC rated operational voltage, Removable terminals and Power Rail |
|
Сегментный согласователь Profibus PA-Segment – Profibus RS 485
KFD2-BR-1.PA.93 |
Segment coupler for PROFIBUS PA, Segment coupler for a non-intrinsically safe PROFIBUS PA segment, PROFIBUS DP, EN 50170/2, RS 485: 93.75 kBit/s, PROFIBUS PA, PROFIBUS EN 50170/2, IEC 61158-2: 31.25 kBit/s, Master independent, Up to 32 PROFIBUS PA participants can be connected to a segment, Supply via PA bus |
|
Сегментный согласователь Modbus RTU-Segment – Modbus RS 485
KFD2-BR-Ex1.3MOD.38 |
Segment coupler for MODBUS RTU, Segment coupler for intrinsically safe MODBUS RTU segment, MODBUS RTU [EEx ia] IIC IEC 61158-2: 31.25 kBit/s, Master independent, Up to 32 devices can be connected to RS 485 segment, up to 6 devices to the [EEx ia] segment, 24 V DC rated operational voltage, Removable terminals and Power Rail |
|
Сегментный согласователь Profibus PA-Segment – Profibus RS 485
KFD2-BR-Ex1.3PA.93 |
Segment coupler for PROFIBUS PA, Segment coupler for intrinsically safe PROFIBUS PA segment, PROFIBUS DP, EN 50170/2, RS 485: 93.75 kBit/s, PROFIBUS PA [EEx ia] IIC, PROFIBUS EN 50170/2, IEC 61158-2: 31.25 kBit/s, Master independent, Up to 10 Ex devices can be connected to the PA segment, Supply via PA bus |
|
Разделительный преобразователь ток/напряжение
KFD2-CD-1.32 |
1-channel, 24 V DC supply voltage, Conversion of current/voltage or voltage/current, Elevation of the ‘life zero’, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: 20 … 35 V DC within the supply tolerance, SIL/IEC 61508, Explosion protection: No Ex-protection, Field circuit: 0(4)-20 mA, Safe area: 0(4)-20 mA, Transfer direction: To the field |
|
Разделительный преобразователь для тока
KFD2-CD2-Ex1 |
1-channel, Output EEx ia IIC, Device installation permissible in zone 2, Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: 10 … 35 V DC, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: To the field |
|
Разделительный преобразователь для тока
KFD2-CD2-Ex2 |
2-channel, Output EEx ia IIC, Device installation permissible in zone 2, Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: 10 … 35 V DC, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: To the field |
|
Разделительный преобразователь ток/напряжение
KFD2-CD-Ex1.32 |
1-channel, Output EEx ia IIC, 24 V DC supply voltage, Device installation permissible in zone 2, Conversion of current/voltage or voltage/current, Elevation/Suppression of the ‘life zero’, Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Explosion protection: Ex protection, Field circuit: 0(4)-20 mA, Safe area: 0(4)-20 mA, Transfer direction: To the field |
|
Трансмиттер
KFD2-CR-1.300 |
1-channel, 24 V DC nominal supply voltage, Galvanic isolated measuring circuits, Output: allowable load <= 1 kOhm, EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 0 … 20 mA / 4 … 20 mA, Input, current source, Explosion protection: No Ex-protection |
|
Трансмиттер
KFD2-CR4-1 |
1-channel, Device installation permissible in zone 2, Galvanically isolated output, 24 V DC supply voltage, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure |
|
Трансмиттер
KFD2-CR4-1.2O |
1-channel, 2 galvanically isolated outputs, 24 V DC nominal supply voltage, EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 32 V DC, Output signal: 0 … 20 mA, Dual output, Input, current source, Explosion protection: No Ex-protection |
|
Трансмиттер
KFD2-CR4-2 |
2-channel, Device installation permissible in zone 2, 24 V DC supply voltage, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure |
|
Трансмиттер
KFD2-CR-Ex1.20200 |
1-channel, Input EEx ia IIC, U 0 = 20V, use standard type KFD2-STC4-Ex1 with U 0 = 25.2 V, 24 V DC nominal supply voltage, Output: allowable load max. 1 kOhm, EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 4 … 20 mA, Explosion protection: Ex-Input |
|
Трансмиттер
KFD2-CR-Ex1.20300 |
1-channel, Input EEx ia IIC, U 0 = 20V, use standard type KFD2-STC4-Ex1 with U 0 = 25.2 V, 24 V DC nominal supply voltage, Output: allowable load max. 1 kOhm, EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 0 … 20 mA or 4 … 20 mA, Input, current source, Explosion protection: Ex-Input |
|
Трансмиттер
KFD2-CR-Ex1.20340 |
1-channel, Input EEx ia IIC, U 0 = 20V, use standard type KFD2-CRG-Ex1.D with U 0 = 25.8 V, 24 V DC nominal supply voltage, Output: allowable load max. 1 kOhm, EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 0 … 20 mA, Input, current source, Explosion protection: Ex-Input |
|
Трансмиттер
KFD2-CR-Ex1.30200 |
1-channel, Input EEx ia IIC, U 0 = 26 V, 24 V DC nominal supply voltage, Output: allowable load max. 1 kOhm, EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 0 … 20 mA or 4 … 20 mA, Explosion protection: Ex-Input |
|
Трансмиттер
KFD2-CR-Ex1.30300 |
1-channel, Input EEx ia IIC, U 0 = 26 V, 24 V DC nominal supply voltage, Output: allowable load max. 1 kOhm, EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 0 … 20 mA or 4 … 20 mA, Input, current source, Explosion protection: Ex-Input |
|
Трансмиттер
KFD2-CR-Ex1.30340 |
1-channel, Input EEx ia IIC, U 0 = 26 V, 24 V DC nominal supply voltage, Output: allowable load max. 1 kOhm, EMC acc. to NAMUR NE 21, Directive 94/9 EC: EN 50014, EN 50020, EN 50021, Electromagnetic compatibility: standards, Directive 89/336/EC: EN 61326, EN 50081-2, NE 21, Group, category, type of protection: [exsign] II (1) G D [EEx ia] IIC (-20 °C <= T a <= 60 °C) [circuit(s) in zone 0/1/2], Input/Output: safe electrical isolation acc. to EN 50020, voltage peak value 375 V |
|
Трансмиттер
KFD2-CRG-1.D |
1-channel, Analogue input 0/4 mA … 20 mA, Analogue output 0/4 mA … 20 mA, 2 relay outputs, Each relay output individually parameterisable as high or low alarm or error message output, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Parameterisation via PC or control panel (optional), Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 30 V DC, SIL/IEC 61508, Output signal: 0 … 20 mA or 4 … 20 mA, Limit alarm relay |
|
Трансмиттер
KFD2-CRG-Ex1.D |
1-channel, Analogue input 0/4 mA … 20 mA EEx ia IIC, Analogue output 0/4 mA … 20 mA, 2 relay outputs, Each relay output individually parameterisable as high/low alarm, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Parameterisation via PC or control panel, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 30 V DC, SIL/IEC 61508, Output signal: 0 … 20 mA, Limit alarm relay, Display, Input, current source |
|
Трансмиттер
KFD2-DU-Ex1.D |
1-channel, Control circuit EEx ia IIC, Switching amplifier with timing, Maximum input frequency 80 Hz, 1 relay output, 1 potential-free electronic output, Pulse divider up to 1 kHz, Time function: one shot output, one shot output retrigger, pulse extension, pulse limitation , on-delay, off-delay, auxiliary switch, Time range of the output function from 10 ms … 60 min, Reset function, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC |
|
Модуль контроля частоты импульсов, Контроллер частоты вращения
KFD2-DWB-1.D |
1-channel, Input frequency 1 mHz … 12 kHz, 2 relay outputs, Each output individually parameterisable as trip value, Start-up override, Restart inhibit, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Bounce filter, Parameterisation via control panel, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Function(P2P): Limit value, Output: 2 x 1 Changeover contact, Display, Explosion protection: No Ex-protection |
|
Модуль контроля частоты импульсов, Контроллер частоты вращения
KFD2-DWB-Ex1.D |
1-channel, Control circuit EEx ia IIC, Input frequency 0.001 Hz … 5 kHz, 2 relay outputs, Each output individually parameterisable as trip value, Start-up override, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Restart inhibit, Bounce filter, Parameterisation via control panel, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Function(P2P): Limit value, Output: 2 x 1 Changeover contact, Display, Explosion protection: Ex-Input |
|
Запитывающий модуль
KFD2-EB.D2A.B |
24 V DC supply voltage, Device installation permissible in zone 2, Supply current <= 2 A, Bus access via terminals, Redundant supply, Fault signal output with adjustable mode of operation, EMC acc. to NAMUR NE 21 |
|
Запитывающий модуль
KFD2-EB.MAR.RPI |
24 V DC supply voltage, Supply current <= 2 A, Bus access via terminals, Redundant supply, Fault signal output with adjustable mode of operation |
|
Запитывающий модуль
KFD2-EB.R2A.B |
24 V DC nominal supply voltage, Device installation permissible in zone 2, Supply current <= 2 A, Bus access via terminals, Redundant supply, Fault signal output with adjustable mode of operation, EMC acc. to NAMUR NE 21 |
|
Запитывающий модуль
KFD2-EB.R2A.RPI |
24 V DC supply voltage, Device installation permissible in zone 2, Supply current <= 2 A, Bus access via terminals, Redundant supply |
|
Запитывающий модуль
KFD2-EB.RPI |
24 V DC supply voltage, Device installation permissible in zone 2, Supply current <= 4 A, Fault signal output with adjustable mode of operation, Bus access via terminals |
|
Запитывающий модуль
KFD2-EB2 |
24 V DC nominal supply voltage, Device installation permissible in zone 2, Supply current <= 4 A, Fault signal output with adjustable mode of operation, EMC acc. to NAMUR NE 21 |
|
Запитывающий модуль
KFD2-EB2.B |
24 V DC nominal supply voltage, Device installation permissible in zone 2, Supply current <= 4 A, Fault signal output with adjustable mode of operation, EMC acc. to NAMUR NE 21 |
|
16-канальный модуль контроля заземления
KFD2-ELD-Ex16 |
16-channel, Control circuit EEx ia IIC, Power supply via Power Rail or via removable terminals, 1 LED per channel as an error indicator, Collective error message output with 1 change-over contact, Reversible mode of operation, Test input, 24 V DC nominal supply voltage, Additional collective error message via Power Rail |
|
Электродное реле (реле коннтроля на прикосновение)
KFD2-ER-1.5 |
1-channel, Relay for conductive limit value detection, Adjustable sensitivity, Measuring circuit in acc. with VDE 0100 part 410 ‘Funktionskleinspannung’, Minimum/maximum control |
|
Электродное реле (реле коннтроля на прикосновение)
KFD2-ER-1.6 |
1-channel, Relay for conductive limit value detection, Adjustable sensitivity, Measuring circuit in acc. with VDE 0100 part 410 ‘Funktionskleinspannung’, Minimum/maximum control |
|
Электродное реле (реле коннтроля на прикосновение)
KFD2-ER-1.W.LB |
1-channel, Relay for conductive limit value detection, Minimum/maximum control, On/off control system, Open/closed circuit current principle switchable |
|
Электродное реле (реле коннтроля на прикосновение)
KFD2-ER-2.W.LB |
2-channel, Relay for conductive limit value detection, Minimum/maximum control, On/off control system, Open/closed circuit current principle switchable |
|
Электродное реле (реле коннтроля на прикосновение)
KFD2-ER-Ex1.W.LB |
1-channel, Relay for conductive limit value detection, Minimum/maximum control, On/off control system, Open/closed circuit current principle switchable |
|
Разделитель RS 232
KFD2-FF-Ex2.RS232 |
RS 232 transmission, Corresponds to EIA standard RS 232C and RS 232D, Field circuit EEx ia IIC, Bi-directional transmission, Rated voltage: 15 … 35 V DC, Explosion protection: Ex protection, Field circuit: RS 232, Safe area: RS 232, Transfer direction: to the field |
|
Реле предельного значения для сигналов ток-/напряжение
KFD2-GS-1.2W |
1-channel, 24 V DC nominal supply voltage, 2 switching points operate on 2 output relays (changeover contacts) or limit value 1 actuates both output relays (DIP switch S1.6 in ON position), Measuring sockets for switching point (limit value) and actual value, High/low alarm settable, Mode of operation adjustable, Hysteresis 0,% … 60,% of measuring range, adjustable, EMC acc. to NAMUR NE 21, Rated voltage: 20 … 30 V DC, Output: 2 x 1 changeover contact, Explosion protection: No Ex-protection |
|
Реле предельного значения
KFD2-GU-1 |
1-channel, 24 V DC nominal supply voltage, 2 switch outputs, High/low alarm selectable, Mode of operation adjustable, Adjustment option of 0 V … 10 V, 0 mA … 20 mA, of Pt100, Ni100 or thermocouple (B, E, J, K, L, N, R, S or T), Internal or external cold junction compensation, Sensor burnout monitoring for thermocouples, Sensor burnout and short-circuit monitoring for Pt100, current and voltage, Online adjustments via serial interface to PC, EMC acc. to NAMUR NE 21, Rated voltage: 20 … 35 V DC |
|
Реле предельного значения
KFD2-GU-Ex1 |
1-channel, Input EEx ia IIC, 2 relay outputs, High/low alarm settable, Mode of operation adjustable, Inputs for voltage (0 V … 10 V), current (0 mA … 20 mA) RTDs (Pt100, Ni100) thermocouples (B, E, J, K, L, N, R, S, or T), Sensor burnout monitoring for thermocouples, Sensor burnout and short-circuit monitoring for Pt100, Online adjustments via serial interface to PC, EMC acc. to NAMUR NE 21, Rated voltage: 20 … 35 V DC, Output: 2 x 1 Changeover contact, Explosion protection: Ex-Input |
|
Температурный измерительный преобразователь с функцией предельного значения
KFD2-GUT-1.D |
1-channel, Input for voltage 0 V … 1 V, 0 V … 10 V, -100 mV … +100 mV, Input RTD: Pt100, Pt500, Pt1000, Ni100,Ni1000 2-, 3- and 4-wire, Input potentiometer 800 Ohm … 20 kOhm 2-, 3- and 5-wire, Input thermocouple type B, E, J, K, L, N, R, S, T, Redundant input for thermocouple for plausibility check, Sensor burnout monitoring, 2 relay outputs, Each relay output individually parameterisable as high/low alarm, Analogue output 0/4 mA … 20 mA, Manual adjustments or adjustments via PC |
|
Температурный измерительный преобразователь с функцией предельного значения
KFD2-GUT-Ex1.D |
1-channel, Input EEx ia IIC, Input for voltage 0 V … 1 V, 0 V … 10 V, -100 mV … +100 mV, Input RTD: Pt100, Pt500, Pt1000, Ni100,Ni1000 2-, 3- and 4-wire, Input potentiometer 800 Ohm … 20 kOhm 2-, 3- and 5-wire, Input thermocouple type B, E, J, K, L, N, R, S, T, Redundant input for thermocouple for plausibility check, Sensor burnout monitoring, 2 relay outputs, Each relay output individually parameterisable as high/low alarm, Analogue output 0/4 mA … 20 mA, Input: Temperature |
|
HART-Multiplexer-Master
KFD2-HMM-16 |
24 V DC supply voltage, Up to 15 KFD0-HMS-16 slave units can be connected, 14-pin flat cable for connection to master/slave unit, Subordinate service level, For use within the framework of the quality assurance program in accordance with ISO 9000 for online equipment monitoring, Maintenance system, Up to 7936 loops on one interface, Removable terminals and Power Rail, SIL1 up to SIL3 acc. to IEC 61508 |
|
Разделительный преобразователь для потенциометров
KFD2-PT2-Ex1** |
1-channel, Input EEx ia IIC, 24 V DC nominal supply voltage, Current or voltage output, Accuracy 0.05 %, EMC acc. to NAMUR NE 21 |
|
Разделительный преобразователь для потенциометров
KFD2-PT2-Ex1-5 |
1-channel, Input EEx ia IIC, 24 V DC nominal supply voltage, Current or voltage output, Accuracy 0.05 %, EMC acc. to NAMUR NE 21 |
|
Разделительный преобразователь для термоэлементов
KFD2-RR-Ex1 |
1-channel, Input EEx ia IIC, Device installation permissible in zone 2, 24 V DC nominal supply voltage, Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Rated voltage: 20 … 35 V DC, Explosion protection: Ex protection, Field circuit: Resistance, Safe area: Resistance, Transfer direction: |
|
SMART-разделительный преобразователь
KFD2-SCD2-1.LK |
1-channel, Lead breakage (LB) monitoring and short-circuit (SC) monitoring via Power Rail, Conductive for HART communication (galvanically isolated), Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: 10 … 35 V DC, SIL/IEC 61508, HART transfer, Explosion protection: No Ex-protection, Field circuit: 4-20 mA, HART, Safe area: 4-20 mA, HART, Transfer direction: To the field |
|
SMART-разделительный преобразователь
KFD2-SCD2-2.LK |
2-channel, Lead breakage (LB) monitoring and short-circuit (SC) monitoring via Power Rail, Conductive for HART communication (galvanically isolated), Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: 10 … 35 V DC, SIL/IEC 61508, HART transfer, Explosion protection: No Ex-protection, Field circuit: 4-20 mA, HART, Safe area: 4-20 mA, HART, Transfer direction: To the field |
|
SMART-разделительный преобразователь
KFD2-SCD2-Ex1.LK |
1-channel, Output EEx ia IIC, Lead breakage (LB) monitoring and short-circuit (SC) monitoring via Power Rail, Conductive for HART communication (galvanically isolated), Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: 10 … 35 V DC, SIL/IEC 61508, HART transfer, Explosion protection: Ex protection, Field circuit: 4-20 mA, HART, Safe area: 4-20 mA, HART, Transfer direction: To the field |
|
SMART-разделительный преобразователь
KFD2-SCD2-Ex2.LK |
2-channel, Output EEx ia IIC, Lead breakage (LB) monitoring and short-circuit (SC) monitoring via Power Rail, Conductive for HART communication (galvanically isolated), Accuracy 0.1 %, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: 10 … 35 V DC, SIL/IEC 61508, HART transfer, Explosion protection: Ex protection, Field circuit: 4-20 mA, HART, Safe area: 4-20 mA, HART, Transfer direction: To the field |
|
SMART-разделительный преобразователь
KFD2-SCD-Ex1.LK |
1-channel, Output EEx ia IIC, Device installation permissible in zone 2, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Conductive for HART communication (galvanically isolated), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, HART transfer, Explosion protection: Ex protection, Field circuit: 4-20 mA, HART, Safe area: 4-20 mA, HART, Transfer direction: To the field |
|
Модуль управления клапанами
KFD2-SD-Ex1.17 |
1-channel, Device installation permissible in zone 2, Output EEx ia IIC, Current limit: 65 mA, SIL1 up to SIL3 acc. to IEC 61508, Input: ohne Vorlogik, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex-Output, Output rated operating current: 65 mA |
|
Модуль управления клапанами
KFD2-SD-Ex1.36 |
1-channel, Output EEx ia IIB, Device installation permissible in zone 2, Current limit: 80 mA, SIL1 up to SIL3 acc. to IEC 61508, Input: ohne Vorlogik, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex-Output, Output rated operating current: max. 80 mA |
|
Модуль управления клапанами
KFD2-SD-Ex1.48 |
1-channel, Output EEx ia IIC, Device installation permissible in zone 2, SIL1 up to SIL3 acc. to IEC 61508, Input: ohne Vorlogik, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex-Output, Output rated operating current: 35 mA |
|
Модуль управления клапанами
KFD2-SD-Ex1.48.90A |
1-channel, Output EEx ia IIC, Device installation permissible in zone 2, SIL1 up to SIL3 acc. to IEC 61508, Input: ohne Vorlogik, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex-Output, Output rated operating current: 45 mA |
|
Разделительный усилитель
KFD2-SH-Ex1 |
1-channel, Control circuit EEx ia IIC, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, 1 safety-oriented relay output SIL3 acc. to IEC/EN 61508 and acc. to DIN VDE 0660, part 209, Product classification in accordance with ISO 13489-1 (EN 954-1 category 3), 1 relay output repeats the state of the input circuit, 1 passive electronic output, error message, EMC acc. to NAMUR NE 21, Input: NAMUR sensor, Rated voltage: 20 … 35 V DC, Output: Relay, SIL/IEC 61508, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-SH-Ex1.T.OP |
1-channel, Control circuit EEx ia IIC, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, 1 safety-oriented active electronic output SIL3 acc. to IEC/EN 61508 and acc. to DIN VDE 0660, part 209, Product classification in accordance with ISO 13849-1 (EN 954-1 category 3), 1 relay output repeats the state of the input circuit, 1 error message output with 1 NO, EMC acc. to NAMUR NE 21, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor, SIL/IEC 61508 |
|
Модуль управления клапанами
KFD2-SL2-Ex1 |
1-channel, Output EEx ia IIC, 24 V DC supply voltage, Output current max. 45 mA, Logic input non-polarised, EMC acc. to NAMUR NE 21, Lead monitoring: LED flashing red and signal via Power Rail, LED accord. to NAMUR NE 44, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: mit Vorlogik, Rated voltage: 20 … 30 V DC, SIL/IEC 61508, Explosion protection: Ex-Output, Fault message output, Output rated operating current: 45 mA |
|
Модуль управления клапанамиKFD2-SL2-Ex1.B |
1-channel, Output EEx ia IIC, 24 V DC supply voltage, Output current max. 45 mA, Logic input non-polarised, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: mit Vorlogik, Rated voltage: 20 … 30 V DC, SIL/IEC 61508, Explosion protection: Ex-Output, Output rated operating current: 45 mA |
|
Модуль управления клапанами
KFD2-SL2-Ex1.LK |
1-channel, Output EEx ia IIC, Lead monitoring: red LED, flashing, signal on Power Rail and output error message de-energised, 24 V DC supply voltage, Output current max. 45 mA, Logic inputs, non-polarised, Removable terminals, EMC acc. to NAMUR NE 21, LED accord. to NAMUR NE 44, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: mit Vorlogik, Rated voltage: 20 … 30 V DC, SIL/IEC 61508, Explosion protection: Ex-Output, Fault message output, Output rated operating current: 45 mA |
|
Модуль управления клапанами
KFD2-SL2-Ex2 |
2-channel, Output EEx ia IIC, Lead monitoring: LED flashing red and signal via Power Rail, Output current max. 45 mA, Logic inputs, non-polarised, EMC acc. to NAMUR NE 21, LED accord. to NAMUR NE 44, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: mit Vorlogik, Rated voltage: 20 … 30 V DC, SIL/IEC 61508, Explosion protection: Ex-Output, Fault message output, Output rated operating current: 45 mA |
|
Модуль управления клапанами
KFD2-SL2-Ex2.B |
2-channel, Output EEx ia IIC, 24 V DC supply voltage, Output current max. 45 mA, Logic inputs, non-polarised, EMC acc. to NAMUR NE 21, LED accord. to NAMUR NE 44, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: mit Vorlogik, Rated voltage: 20 … 30 V DC, SIL/IEC 61508, Explosion protection: Ex-Output, Output rated operating current: 45 mA |
|
Модуль управления клапанами, усилитель мощности
KFD2-SL-4 |
4-channel, Control via logic inputs, 24 V DC supply voltage, Output current: 600 mA/channel (resistive, inductive, capacitive load), All channels can be simultaneously turned off via a galvanically isolated input., Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: mit Vorlogik, Rated voltage: 20 … 30 V DC, SIL/IEC 61508, Explosion protection: No Ex-protection, Fault message output, Output rated operating current: 600 mA |
|
Модуль управления клапанами
KFD2-SL-Ex1.48 |
1-channel, Output EEx ia IIC, 24 V DC supply voltage, Logic input for connection and disconnection, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: mit Vorlogik, Rated voltage: 5 … 35 V DC, SIL/IEC 61508, Explosion protection: Ex-Output, Output rated operating current: 35 mA |
|
Модуль управления клапанами
KFD2-SL-Ex1.48.90A |
1-channel, Output EEx ia IIC, 24 V DC supply voltage, Logic input for connection and disconnection, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: mit Vorlogik, Rated voltage: 5 … 35 V DC, SIL/IEC 61508, Explosion protection: Ex-Output, Output rated operating current: 45 mA |
|
Разделительный усилитель
KFD2-SOT2-Ex1.LB |
1-channel, Control circuit EEx ia IIC, Device installation permissible in zone 2, Reversible mode of operation, Output I: signal output (passive electronic output, non-polarised) Output II: either signal output or error message (passive electronic output, non-polarised), EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Optocoupler |
|
Разделительный усилитель
KFD2-SOT2-Ex1.LB.IO |
1-channel, Control circuit EEx ia IIC, Device installation permissible in zone 2, Reversible mode of operation, Output I: signal output (passive electronic output, non-polarised) Output II: either signal output or error message (passive electronic output, non-polarised), Output I and Output II galvanically isolated, EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor |
|
Разделительный усилитель
KFD2-SOT2-Ex2 |
2-channel, Control circuit EEx ia IIC, Device installation permissible in zone 2, Reversible mode of operation, 1 passive transistor output, depolarized per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Optocoupler, SIL/IEC 61508, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-SOT2-Ex2.IO |
2-channel, Control circuit EEx ia IIC, Device installation permissible in zone 2, Reversible mode of operation, 1 passive transistor output, depolarized per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Optocoupler, SIL/IEC 61508, Separate outputs, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-SOT-Ex1 |
1-channel, Control circuit EEx ia IIC, 24 V DC nominal supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, 1 passive electronic output, EMC acc. to NAMUR NE 21, Input: NAMUR sensor, Rated voltage: 20 … 35 V DC, Output: Optocoupler, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-SOT-Ex2 |
2-channel, Control circuit EEx ia IIC, 24 V DC nominal supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, 1 passive electronic output per channel, EMC acc. to NAMUR NE 21, Input: NAMUR sensor, Rated voltage: 20 … 35 V DC, Output: Optocoupler, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-SR2-2.2S |
2-channel, Reversible mode of operation, 1 relay output per channel with 2 NO each, EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Usable up to SIL 2 acc. to IEC 61508 , Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: relay, SIL/IEC 61508, Explosion protection: No Ex-protection |
|
Stillstandswächter
KFD2-SR2-2.W.SM |
1-channel standstill controller, Rotation direction detection or start-up override selectable, 2 relay outputs, Input frequency <= 2 kHz, Diagnosis LEDs for rotation detection, signal below the trip value, operating voltage and hardware error |
|
Разделительный усилитель
KFD2-SR2-Ex1.W |
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay output with 1 changeover contact, EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Relay, SIL/IEC 61508, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-SR2-Ex1.W.LB |
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, Output I: signal output (changeover contact), Output II: optionally signal output/fault signal, EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Relay, SIL/IEC 61508, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-SR2-Ex2.2S |
2-channel, Control circuit EEx ia IIC, Device installation permissible in zone 2, Reversible mode of operation, 1 relay output per channel with 2 NO each, EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Relay, SIL/IEC 61508, Explosion protection: Ex-Input |
|
2-канальный контактный разделитель
KFD2-SR2-Ex2.W |
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 signal output with 1 changeover contact per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure |
|
Модуль сигнализации остановки (аварийной остановки)
KFD2-SR2-Ex2.W.SM |
1-channel, Control circuit EEx ia IIC, Additional input for rotation direction detecion or start-up override, 2 relay outputs, Input frequency <= 2 kHz, EMC acc. to NAMUR NE 21, Diagnosis LEDs for rotation detection, signal below the trip value, operating voltage and hardware error, LB/SC monitoring, Collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Function(P2P): Grenzwert+Drehrichtung/Schlupf, Output: 2 x 1 Changeover contact, SIL/IEC 61508 |
|
Разделительный усилитель
KFD2-SRA-Ex4 |
Control circuit EEx ia IIC, 24 V DC nominal supply voltage, Reversible mode of operation, Lead monitoring (short-circuit LK and interruption LB) with LED indicator (red flashing), switching output and signal on Power Rail , 50 % less wiring 2:1, 2 relay outputs, 1 NO contact per channel, grouped into single-pole pairs, EMC acc. to NAMUR NE 21, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: relay, 2:1 Method, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-SR-Ex1.4S.LK |
1-channel, Control circuit EEx ia IIC, 24 V DC nominal supply voltage, Reversible mode of operation, Adjustable pulse extension, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, 4 signal outputs, 1 NO contact each, Error message output, NO contact, Input: NAMUR sensor, Rated voltage: 20 … 35 V DC, Output: relay, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-SR-Ex2 |
2-channel, Control circuit EEx ia IIC, 24 V DC rated operational voltage, Reversible mode of operation, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, 1 signal output per channel with 1 NO, Input: NAMUR sensor, Rated voltage: 20 … 35 V DC, Output: relay, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-SRT-Ex1 |
1-channel, Control circuit EEx ia IIC, 24 V DC nominal supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, 1 active electronic output, 1 relay output, EMC acc. to NAMUR NE 21, Input: NAMUR sensor, Rated voltage: 20 … 35 V DC, Output: Relay + Transistor, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-ST2-Ex1.LB |
1-channel, Control circuit EEx ia IIC, Device installation permissible in zone 2, Reversible mode of operation, Output I: signal output (active electronic output) Output II: either signal output or error message (active electronic output), EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure |
|
Разделительный усилитель
KFD2-ST2-Ex2 |
2-channel, Control circuit EEx ia IIC, Device installation permissible in zone 2, Reversible mode of operation, 1 active electronic output per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, LB/SC collective error message via Power Rail, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 … 30 V DC, Output: Transistor, SIL/IEC 61508, Explosion protection: Ex input |
|
SMART-трансмиттер
KFD2-STC1-Ex1 |
1-channel, Input EEx ia IIC, U 0 = 25.5 V, 24 V DC nominal supply voltage, SMART capable up to 12 kHz (-1 dB), EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 4 … 20 mA , max. load 500 Ohm, with HART >= 230 Ohm, HART transfer, Explosion protection: Ex-Input |
|
SMART-трансмиттер
KFD2-STC3-Ex1 |
1-channel, Input EEx ia IIC, U 0 = 25.2 V, 24 V DC nominal supply voltage, SMART capable up to 40 kHz (-1dB), EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 4 … 20 mA , max. load 1000 Ohm , for HART >=230 Ohm, HART transfer, Explosion protection: Ex-Input |
|
SMART-трансмиттер
KFD2-STC4-1 |
1-channel, Galvanically isolated output, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/4 … 20 mA (overload > 25mA), HART transfer, Input, current source, Explosion protection: No Ex-protection |
|
SMART-трансмиттер
KFD2-STC4-1.2O |
1-channel, 2 galvanically isolated outputs, 24 V DC supply voltage, EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/4 … 20 mA (overload > 25mA), HART transfer, Dual output, Input, current source, Explosion protection: No Ex-protection |
|
SMART-трансмиттер
KFD2-STC4-2 |
2-channel, Galvanically isolated output, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/4 … 20 mA (overload > 25mA), HART transfer, Explosion protection: No Ex-protection |
|
SMART-трансмиттер
KFD2-STC4-Ex1 |
1-channel, Device installation permissible in zone 2, Input EEx ia IIC, U o = 25.4 V, Galvanically isolated output, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/4 … 20 mA (overload > 25mA), HART transfer, Input, current source, Explosion protection: Ex input |
|
SMART-трансмиттер
KFD2-STC4-Ex1.2O |
1-channel, Device installation permissible in zone 2, Input EEx ia IIC, U 0 = 25.4 V, 2 galvanically isolated outputs, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/4 … 20 mA (overload > 25mA), HART transfer, Dual output, Input, current source, Explosion protection: Ex-Input |
|
SMART-трансмиттер,
Токовый повторитель
KFD2-STC4-Ex1.2O-Y112668 |
1-channel, Device installation permissible in zone 2, Input EEx ia IIC, U 0 = 25.4 V, 2 galvanically isolated outputs, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/4 … 20 mA (overload > 25mA), HART transfer, Dual output, Output, current sink, Input, current source, Explosion protection: Ex-Input |
|
SMART-трансмиттер,
Токовый повторитель
KFD2-STC4-Ex1-Y112669 |
1-channel, Device installation permissible in zone 2, Input EEx ia IIC, U 0 = 25.4 V, Galvanically isolated output, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/4 … 20 mA (overload > 25mA), HART transfer, Dual output, Output, current sink, Input, current source, Explosion protection: Ex-Input |
|
SMART-трансмиттер,
Токовый повторитель
KFD2-STC4-Ex1-Y122583 |
1-channel, Device installation permissible in zone 2, Input EEx ia IIC, U 0 = 25.4 V, Galvanically isolated output, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/4 … 20 mA (overload > 25mA), HART transfer, Output, current sink, Input, current source, Explosion protection: Ex-Input |
|
SMART-трансмиттер
KFD2-STC4-Ex2 |
2-channel, Input EEx ia IIC, U 0 = 25.2 V, Device installation permissible in zone 2, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/4 … 20 mA (overload > 25mA), HART transfer, Explosion protection: Ex-Input |
|
SMART-трансмиттер
KFD2-STC4-Ex2-Y72195 |
2-channel, Input EEx ia IIC, U 0 = 25.2 V, Device installation permissible in zone 2, 24 V DC supply voltage, EMC acc. to NAMUR NE 21, Output as current sink, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/4 … 20 mA (overload > 25mA), HART transfer, Output, current sink, Explosion protection: Ex-Input |
|
Разделительный усилитель
KFD2-ST-Ex1 |
1-channel, Control circuit EEx ia IIC, 24 V DC nominal supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, 2 active electronic outputs, EMC acc. to NAMUR NE 21, Input: NAMUR sensor, Rated voltage: 20 … 35 V DC, Output: Transistor, Explosion protection: Ex-Input |
|
Обзоры
Отзывов пока нет.