Продукт Краткое описание Datasheet
Разделительный усилитель
KFD2-ST-Ex2
2-channel, Control circuit EEx ia IIC, 24 V DC nominal supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, 1 active electronic output per channel, EMC acc. to NAMUR NE 21, Input: NAMUR sensor, Rated voltage: 20 … 35 V DC, Output: Transistor, Explosion protection: Ex-Input
SMART-трансмиттер
KFD2-STV1-Ex1-1
1-channel, Input EEx ia IIC, U 0 = 25.5 V, 24 V DC nominal supply voltage, SMART capable up to 12 kHz (-1 dB), EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 1 … 5 V , internal resistance approx. 305 Ohm, HART transfer, Explosion protection: Ex-Input
SMART-трансмиттер
KFD2-STV3-Ex1-1
1-channel, Input EEx ia IIC, U 0 = 25.2 V, 24 V DC nominal supply voltage, SMART capable up to 40 kHz (-1dB), EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 1 … 5 V , internal resistance approx. 305 Ohm, HART transfer, Explosion protection: Ex-Input
SMART-трансмиттер
KFD2-STV3-Ex1-2
1-channel, Input EEx ia IIC, U 0 = 25.2 V, 24 V DC nominal supply voltage, SMART capable up to 40 kHz (-1dB), EMC acc. to NAMUR NE 21, Input: , Rated voltage: 20 … 35 V DC, Output signal: 2 … 10 V , internal resistance approx. 305 Ohm, HART transfer, Explosion protection: Ex-Input
SMART-трансмиттер
KFD2-STV4-2-1
2-channel, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/1 … 5 V, HART transfer, Explosion protection: No Ex-protection
SMART-трансмиттер
KFD2-STV4-Ex1.2O-1
1-channel, Device installation permissible in zone 2, Input EEx ia IIC, U o = 25.4 V, 2 galvanically isolated outputs, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/1 … 5 V, HART transfer, Dual output, Input, current source, Explosion protection: Ex input
SMART-трансмиттер
KFD2-STV4-Ex1.2O-2
1-channel, Device installation permissible in zone 2, Input EEx ia IIC, U 0 = 25.4 V, 2 galvanically isolated outputs, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, Output signal: 0/2 … 10 V , load 50 Ohm, HART transfer, Dual output, Input, current source, Explosion protection: Ex-Input
SMART-трансмиттер
KFD2-STV4-Ex1-1
1-channel, Device installation permissible in zone 2, Input EEx ia IIC, U 0 = 25.4 V, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, Output signal: 0/1 … 5 V , load 50 Ohm, HART transfer, Input, current source, Explosion protection: Ex-Input
SMART-трансмиттер
KFD2-STV4-Ex1-2
1-channel, Device installation permissible in zone 2, Input EEx ia IIC, U 0 = 25.4 V, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 35 V DC, Output signal: 0/2 … 10 V, HART transfer, Input, current source, Explosion protection: Ex-Input
Трансмиттер
KFD2-STV4-Ex2-1
2-channel, Input EEx ia IIC, U o = 25.2 V, Device installation permissible in zone 2, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/1 … 5 V, HART transfer, Explosion protection: Ex input
Трансмиттер
KFD2-STV4-Ex2-2
2-channel, Input EEx ia IIC, U o = 25.2 V, Device installation permissible in zone 2, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 … 35 V DC, SIL/IEC 61508, Output signal: 0/2 … 10 V, HART transfer, Explosion protection: Ex input
Модуль контроля частоты импульсов, универсальный преобразователь частоты
KFD2-UFC-1.D
1-channel, Input frequency 1 mHz … 12 kHz, Analogue output 0/4 mA … 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Each output can be assigned individual parameters, such as a trip value (high/low alarm), serially switched output, pulse divider or error message output, Start-up override, Restart inhibit, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Bounce filter, Parameterisation via PC or control panel (optional)
Преобразователь частота/ток с функцией предельного значения
KFD2-UFC-Ex1
1-channel, Control circuit EEx ia IIC, Input frequency 0.001 Hz … 5 kHz, Analogue output 0/4 mA … 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Each output can be assigned individual parameters, such as a trip value (high/low alarm), serially switched output, pulse divider or error message output, Start-up override, Restart inhibit, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Bounce filter
Преобразователь частота/ток с функцией предельного значения
KFD2-UFC-Ex1.D
1-channel, Control circuit EEx ia IIC, Input frequency 0.001 Hz … 5 kHz, Analogue output 0/4 mA … 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Each output can be assigned individual parameters, such as a trip value (high/low alarm), serially switched output, pulse divider or error message output, Start-up override, Restart inhibit, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Bounce filter
Преобразователь частота/ток с функцией контроля предельного значения а также с функцией оповещения о направлении вращения и проворачивания
KFD2-UFT-2.D
2 frequency inputs, 2 control inputs, 2 relay outputs, 2 electronic outputs, isolated, Analogue output 0/4 mA … 20 mA, Lead monitoring (can be deactivated), Parameterisation via control panel, Input frequency 0.001 Hz … 1 kHz (slip monitor function 10 Hz … 1 kHz), Function (P2P): Frequency current converter with trip value and rotation direction/slip, Output: 2 x 1 Changeover contact + 4-20 mA, Display, Explosion protection: No Ex-protection
Преобразователь частота/ток с функцией контроля предельного значения а также с функцией оповещения о направлении вращения и проворачивания
KFD2-UFT-Ex2.D
2 frequency inputs, 2 control inputs, 2 relay outputs, 2 electronic outputs, isolated, Analogue output 0/4 mA … 20 mA, Lead monitoring (can be deactivated), Parameterisation via control panel, Input frequency 0.001 Hz … 1 kHz (slip monitor function 10 Hz … 1 kHz), Function (P2P): Frequency current converter with trip value and rotation direction/slip, Output: 2 x 1 Changeover contact + 4-20 mA, Display, Explosion protection: Ex-Input
Измерительный преобразователь
KFD2-UT-1
1-channel, 24 V DC nominal supply voltage, Accuracy +- 0.1 %, Adjustment option of temperature measuring range for Pt100, Ni100 in 2-, 3- or 4-wire versions, Adjustment option of thermocouple (B, E, J, K, L, N, R, S or T), Freely definable characteristic curve for resistance 0 Ohm … 400 Ohm and voltage -50 mV … +150 mV, Internal or external cold junction compensation, Sensor burnout monitoring for thermocouples, Sensor burnout and short-circuit monitoring (SC) for Pt100, Input: Temperature
Измерительный преобразователь температура/ток (о,4mA…20mA)
KFD2-UT2-1
1-channel, 3-way galvanic isolation, Resistance sensors acc. to IEC 751 or GOST 50353-92, Thermocouples acc. to IEC 584-1, GOST 50431-92 or GOST P85.585-2001, 3-wire resistance (Potentiometer) 800 Ohm … 20 kOhm, Voltage signals between -100 mV and +100 mV, Internal or external cold junction compensation, Sensor burnout and short-circuit monitoring, Collective error message via Power Rail, All settings via serial interface to PC (online parameterisation), EMC acc. to EN 61326
Измерительный преобразователь температура/ток (о,4mA…20mA)
KFD2-UT2-2
2-channel, 1 input/2 outputs freely configurable, 3-way galvanic isolation, Resistance sensors acc. to IEC 751 or GOST 50353-92, Thermocouples acc. to IEC 584-1, GOST 50431-92 or GOST P85.585-2001, 3-wire resistance (Potentiometer) 800 Ohm … 20 kOhm, Voltage signals between -100 mV and +100 mV, Internal or external cold junction compensation, Sensor burnout and short-circuit monitoring, Collective error message via Power Rail, All settings via serial interface to PC (online parameterisation)
Измерительный преобразователь температура/ток (о,4mA…20mA)
KFD2-UT2-Ex1
1-channel, Input EEx ia IIC, 3-way galvanic isolation, Accuracy +- 0.1 %, Resistance sensors acc. to IEC 751 or GOST 50353-92, Thermocouples acc. to IEC 584-1, GOST 50431-92 or GOST P85.585-2001, 3-wire resistance (Potentiometer) 800 Ohm … 20 kOhm, Voltage signals between -100 mV and +100 mV, Internal or external cold junction compensation, Sensor burnout and short-circuit monitoring, Collective error message via Power Rail, All settings via serial interface to PC (online parameterisation)
Измерительный преобразователь температура/ток (о,4mA…20mA)
KFD2-UT2-Ex2
2-channel, Inputs EEx ia IIC, 1 input/2 outputs freely configurable, 3-way galvanic isolation, Accuracy +- 0.1 %, Resistance sensors acc. to IEC 751 or GOST 50353-92, Thermocouples acc. to IEC 584-1, GOST 50431-92 or GOST P85.585-2001, 3-wire resistance (Potentiometer) 800 Ohm … 20 kOhm, Voltage signals between -100 mV and +100 mV, Internal or external cold junction compensation, Sensor burnout and short-circuit monitoring, Collective error message via Power Rail
Измерительный преобразователь
KFD2-UT-Ex1
1-channel, Input EEx ia IIC, 24 V DC supply voltage, Accuracy +- 0.1 %, Adjustment option of temperature measuring range for Pt100, Ni100 in 2-, 3- or 4-wire versions, Adjustment option of thermocouple (B, E, J, K, L, N, R, S or T), Freely definable characteristic curve for resistance 0 Ohm … 400 Ohm and voltage -50 mV … +150 mV, Internal or external cold junction compensation, Sensor burnout monitoring for thermocouples, Sensor burnout and short-circuit monitoring (SC) for Pt100, Input: Temperature
Измерительный преобразователь
KFD2-UT-Ex1-1
1-channel, Input EEx ia IIC, 24 V DC nominal supply voltage, Accuracy +- 0.1 %, Adjustment option of temperature measuring range for Pt100, Ni100 in 2-, 3- or 4-wire versions, Adjustment option of thermocouple (B, E, J, K, L, N, R, S or T), Freely definable characteristic curve for resistance 0 Ohm … 400 Ohm and voltage -50 mV … +150 mV, Internal or external cold junction compensation, Sensor burnout monitoring for thermocouples, Sensor burnout and short-circuit monitoring (SC) for Pt100
Модуль управления клапанами
KFD2-VD-Ex1.1560
1-channel, Output EEx ib IIC, 24 V DC supply voltage, Logic input to switch the field voltage, LED signalling of the switch state, Input: mit Vorlogik, Rated voltage: 20 … 35 V DC, Explosion protection: Ex-Output, Output rated operating current: 60 mA
Модуль управления клапанами
KFD2-VD-Ex1.1835
1-channel, Output EEx ib IIC, 24 V DC nominal supply voltage, Logic input for connection and disconnection, Signalling of the switch state, Input: , Rated voltage: 20 … 35 V DC, Explosion protection: Ex-Output, Output rated operating current: 35 mA
Модуль управления клапанами
KFD2-VM-Ex1.32
1-channel, 2 logic inputs, Output EEx ib IIC, 24 V DC nominal supply voltage, Signalling of the switch state, EMC acc. to NAMUR NE 21, Directive 94/9 EC: EN 50014, EN 50020, Electromagnetic compatibility: standards, Directive 89/336/EC: EN 61326, EN 50081-2, NE 21, Group, category, type of protection: [exsign] II (1) G D [EEx ia] IIC [circuit(s) in zone 0/1/2], Input/Output: safe electrical isolation acc. to EN 50020, voltage peak value 375 V, Ambient temperature: -25 … 60 °C
Модуль управления клапанами
KFD2-VM-Ex1.35.L
1-channel, 3 logic inputs, Service bridging of the output by front connector, Output EEx ia IIC, 24 V DC nominal supply voltage, Signalling of the switch state, EMC acc. to NAMUR NE 21, Directive 94/9 EC: EN 50014, EN 50020, Electromagnetic compatibility: , Directive 89/336/EC: EN 61326, EN 50081-2, NE 21, Group, category, type of protection: [exsign] II (1) G D [EEx ia] IIC [circuit(s) in zone 0/1/2], Input/Output: safe electrical isolation acc. to EN 50020, voltage peak value 375 V
Разделительный преобразователь для напряжений
KFD2-VR4-Ex1.26
1-channel, Input EEx ia IIC, 24 V DC supply voltage, Transfer of AC signals possible, 2-wire sensor with current supply, 3-wire sensor with voltage supply, Rated voltage: 20 … 35 V DC, Explosion protection: Ex protection, Field circuit: 0-20 V, Safe area: 0-20 V
Разделительный преобразователь для напряжений
KFD2-VR-Ex1.18
1-channel, Input EEx ia IIC, 24 V DC nominal supply voltage, EMC acc. to NAMUR NE 21, Rated voltage: 20 … 35 V DC, Explosion protection: Ex protection, Field circuit: 0-12 V, Safe area: 0-12 V, Transfer direction:
Разделительный преобразователь для напряжений
KFD2-VR-Ex1.19
1-channel, Input EEx ia IIC, 24 V DC nominal supply voltage, EMC acc. to NAMUR NE 21, Rated voltage: 20 … 35 V DC, Explosion protection: Ex protection, Field circuit: 0-10 V, Safe area: 0-10 V, Transfer direction:
Разделительный преобразователь для напряжений
KFD2-VR-Ex1.500m
1-channel, Input EEx ia IIC, 24 V DC nominal supply voltage, EMC acc. to NAMUR NE 21, Rated voltage: 20 … 35 V DC, Explosion protection: Ex protection, Field circuit: 0-500 mV, Safe area: 0-500 mV, Transfer direction:
Разделительный преобразователь для напряжений
KFD2-VR-Ex1.50m.L
1-channel, Input EEx ia IIC, Device installation permissible in zone 2, 24 V DC nominal supply voltage, Lead breakage monitoring of the input circuit (L versions), EMC acc. to NAMUR NE 21, Rated voltage: 10 … 40 V DC, Explosion protection: Ex protection, Field circuit: 0-50 mV, Safe area: 0-50 mV, Transfer direction: to the control system
Разделительный преобразователь для напряжений
KFD2-VR-Ex1.50m.R
1-channel, Input EEx ia IIC, Device installation permissible in zone 2, 24 V DC nominal supply voltage, Lead breakage monitoring of the input circuit (R versions), EMC acc. to NAMUR NE 21, Rated voltage: 10 … 40 V DC, Explosion protection: Ex protection, Field circuit: 0-50 mV, Safe area: 0-50 mV, Transfer direction:
Разделительный преобразователь для напряжений
KFD2-VR-Ex1.50m*
1-channel, Input EEx ia IIC, Device installation permissible in zone 2, 24 V DC nominal supply voltage, EMC acc. to NAMUR NE 21, Rated voltage: 10 … 40 V DC, Explosion protection: Ex protection, Field circuit: 0-50 mV, Safe area: 0-50 mV, Transfer direction:
Разделительный преобразователь для напряжений
KFD2-VR-Ex1.50m-Y127104
1-channel, Input EEx ia IIC, 24 V DC nominal supply voltage, Transmission range: 0 mV … +-50 mV, Lead breakage monitoring (can be deactivated), Device installation permissible in zone 2, EMC acc. to NAMUR NE 21, Rated voltage: 10 … 40 V DC, Explosion protection: Ex protection, Field circuit: 0-50 mV, Safe area: 0-50 mV, Transfer direction: To the control system
Измерительный преобразователь для DMS-мостов
KFD2-WAC2-1.D
Full or half bridge load cells and strain gauges, Bridge voltage 1 V DC … 5 V DC, Signal range -100 mV … +100 mV, Sensor burnout monitoring, Tare range: 0 % … 500 %, 2 relay outputs, High/low alarm settable, Analogue output 0/4 mA … 20 mA -20 mA … +20 mA -10 V … +10 V, RS 485 interface, Read in of zero point, adjustement value and range value, Input: DMS bridges, Rated voltage: 20 … 35 V DC, Output: 4-20 mA, Display, Explosion protection: No Ex-protection
Измерительный преобразователь для DMS-мостов
KFD2-WAC2-Ex1.D
Input EEx ia IIC, Full or half bridge load cells and strain gauges, Bridge voltage 2 V DC … 5 V DC, Signal range -100 mV … +100 mV, Sensor burnout monitoring, Tare range 0 % … 500 %, 2 relay outputs, High/low alarm settable, Analogue output 0/4 mA … 20 mA -20 mA … +20 mA -10 V … +10 V, RS 485 interface, Read in of tare, zero point and final value, Input: DMS bridges, Rated voltage: 20 … 35 V DC, Output: 4-20 mA, Display, Explosion protection: Ex-Inputp0
Измерительный преобразователь
KFD2-WAC-Ex1
1-channel, Input EEx ia IIC, Input for 4-wire and 6-wire bridges, Analogue output 0/4 mA … 20 mA or 4 mA … -12 mA, Full bridge load cells and strain gauges, Power circuit for resistance bridges up to 17 Ohm, Bridge voltage 1 V DC … 10 V DC, Measuring span 1.2 mV … 40 mV, Tare range: 0 % … 500 %, Input: DMS bridges, Rated voltage: 20 … 35 V DC, Output: 4-20 mA, Explosion protection: Ex-Input
Измерительный преобразователь
KFD2-WAV-Ex1
1-channel, Input EEx ia IIC, Input for 4-wire and 6-wire bridges, Analogue output 0/2 V … 10 V or 2 V … -6 V, Full bridge load cells and strain gauges, Power circuit for resistance bridges up to 17 Ohm, Bridge voltage 1 V DC … 10 V DC, Measuring span 1.2 mV … 40 mV, Tare range: 0 % … 500 %, Input: DMS bridges, Rated voltage: 20 … 35 V DC, Output: 4-20 mA, Explosion protection: Ex-Input
Трансмиттер
KFU8-CRG-1.D
1-channel, Analogue input 0/4 mA … 20 mA, Analogue output 0/4 mA … 20 mA, 2 relay outputs, Each relay output individually parameterisable as high or low alarm or error message output, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Parameterisation via PC or control panel (optional), Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 90 V DC or 48 … 253 V AC, SIL/IEC 61508, Output signal: 0 … 20 mA or 4 … 20 mA
Трансмиттер
KFU8-CRG-Ex1.D
1-channel, Analogue input 0/4 mA … 20 mA EEx ia IIC, Analogue output 0/4 mA … 20 mA, 2 relay outputs, Each relay output individually parameterisable as high/low alarm, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Parameterisation via PC or control panel, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Input: 3-wire transmitter, Rated voltage: 20 … 90 V DC or 48 … 253 V AC, SIL/IEC 61508, Output signal: 0 … 20 mA or 4 … 20 mA, Limit alarm relay, Display
Контроллер скорости вращения
KFU8-DW-1.D
Rotational speed monitoring up to 5 kHz, 1 pre-select value with relay output and LED indicator, Multi-range power pack, 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable, Start-up delay, Function: Limit value, Output: 2 x 1 Changeover contact, Display, Explosion protection: No Ex-protection
Модуль контроля частоты импульсов,
Контроллер частоты вращения
KFU8-DWB-1.D
1-channel, Input frequency 1 mHz … 12 kHz, 2 relay outputs, Each output individually parameterisable as trip value, Start-up override, Restart inhibit, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Bounce filter, Parameterisation via control panel, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Function(P2P): Limit value, Output: 2 x 1 Changeover contact, Display, Explosion protection: No Ex-protection
Преобразователь частота/напряжение/ток
KFU8-FSSP-1.D
Limit frequency 40 kHz, Voltage or current ouptput, Incrementing output (Spacing factor 1 … 9999), Multi-range power pack, 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable
Преобразователь частота/напряжение/ток
KFU8-FSSP-1.D-Y180599
Limit frequency 40 kHz, Voltage or current ouptput, Incrementing output (Spacing factor 1 … 9999), Multi-range power pack, 2-, 3-, 4-wire sensors and rotary encoder can be connected
Температурный измерительный преобразователь с функцией предельного значения
KFU8-GUT-1.D
1-channel, Input for voltage 0 V … 1 V, 0 V … 10 V, -100 mV … +100 mV, Input RTD: Pt100, Pt500, Pt1000, Ni100,Ni1000 2-, 3- and 4-wire, Input potentiometer 800 Ohm … 20 kOhm 2-, 3- and 5-wire, Input thermocouple type B, E, J, K, L, N, R, S, T, Redundant input for thermocouple for plausibility check, Sensor burnout monitoring, 2 relay outputs, Each relay output individually parameterisable as high/low alarm, Analogue output 0/4 mA … 20 mA, Manual adjustments or adjustments via PC
Температурный измерительный преобразователь с функцией предельного значения
KFU8-GUT-Ex1.D
1-channel, Input EEx ia IIC, Input for voltage 0 V … 1 V, 0 V … 10 V, -100 mV … +100 mV, Input RTD: Pt100, Pt500, Pt1000, Ni100,Ni1000 2-, 3- and 4-wire, Input potentiometer 800 Ohm … 20 kOhm 2-, 3- and 5-wire, Input thermocouple type B, E, J, K, L, N, R, S, T, Redundant input for thermocouple for plausibility check, Sensor burnout monitoring, 2 relay outputs, Each relay output individually parameterisable as high/low alarm, Analogue output 0/4 mA … 20 mA, Input: Temperature
Модуль контроля частоты импульсов, universeller Frequenzumsetzer
KFU8-UFC-1.D
1-channel, Input frequency 1 mHz … 12 kHz, Analogue output 0/4 mA … 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Start-up override, Restart inhibit, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Bounce filter, Parameterisation via PC or control panel (optional), Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Function(P2P): Frequency current converter + trip value, Output: 2 x 1 Changeover contact + 4-20 mA, Display
Преобразователь частота/ток с функцией предельного значения
KFU8-UFC-Ex1
1-channel, Control circuit EEx ia IIC, Input frequency 0.001 Hz … 5 kHz, Analogue output 0/4 mA … 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Each output can be assigned individual parameters, such as a trip value (high/low alarm), serially switched output, pulse divider or error message output, Start-up override, Restart inhibit, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Bounce filter
Преобразователь частота/ток с функцией предельного значения
KFU8-UFC-Ex1.D
1-channel, Control circuit EEx ia IIC, Input frequency 0.001 Hz … 5 kHz, Analogue output 0/4 mA … 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Start-up override, Restart inhibit, Lead breakage (LB) monitoring and short-circuit (SC) monitoring, Bounce filter, Up to SIL2 acc. to IEC 61508, up to SIL3 for a redundant structure, Function(P2P): Frequency current converter + trip value, Output: 2 x 1 Changeover contact + 4-20 mA, Display
Преобразователь частота/ток с функцией контроля предельного значения а также с функцией оповещения о направлении вращения и проворачивания
KFU8-UFT-2.D
2 frequency inputs, 2 control inputs, 2 relay outputs, 2 electronic outputs, isolated, Analogue output 0/4 mA … 20 mA, Lead monitoring (can be deactivated), Parameterisation via control panel, Input frequency 0.001 Hz … 1 kHz (slip monitor function 10 Hz … 1 kHz), Function (P2P): Frequency current converter with trip value and rotation direction/slip, Output: 2 x 1 Changeover contact + 4-20 mA, Display, Explosion protection: No Ex-protection
Преобразователь частота/ток с функцией контроля предельного значения а также с функцией оповещения о направлении вращения и проворачивания
KFU8-UFT-Ex2.D
2 frequency inputs, 2 control inputs, 2 relay outputs, 2 electronic outputs, isolated, Analogue output 0/4 mA … 20 mA, Lead monitoring (can be deactivated), Parameterisation via control panel, Input frequency 0.001 Hz … 1 kHz (slip monitor function 10 Hz … 1 kHz), Function (P2P): Frequency current converter with trip value and rotation direction/slip, Output: 2 x 1 Changeover contact + 4-20 mA, Display, Explosion protection: Ex-Input